Image of a slate-chalkboard with outdoor UPS as the main topic.Outdoor ac output UPS

Battery backup ac power with wide temperature batteries and built-in heavy duty surge protection for harsh and extreme outdoor environments

Outdoor UPS (uninterruptible power systems) manufactured by TSi Power are available in a variety of sizes and ruggedized outdoor enclosures, with wide temperature batteries, and are typically semi-customized, build to order units per your application requirements. As some of today's electronics are very small, some outdoor UPS are available designed with extra space inside to house your OEM systems, so that you have one less outdoor enclosure to deal with. Outdoor UPS or outdoor uninterruptible power systems, (also called uninterruptible power supplies, but usually just UPS or battery backup systems), are for where uptime is critical to an operation's mission fulfillment. Typical UPS backup times are from 8 to 20 minutes, and can be as long as 14 hours for some systems. If even longer times are desirable, choose an outdoor uninterruptible power supply with extra battery cabinet flexibility, and/or enough extra reserve batteries to satisfy your UPS requirements.

Please look at the Outdoor Series features table at the bottom of the page, or the descriptions below, to determine the OutdoorUPs/XUPs series elements you need. If you then want more detailed specifications, click on the model's hyperlink. If you need dc output UPS, please click on the link in the top menu/navigation section or here for outdoor dc output UPS.

Choosing the optimal size UPS for your application

Please remember that your actual measured true RMS current/amperage is what will determine your backup time, not your electronics' nameplate ratings, which sometimes are double or even triple what the actual amperage (or watts) is that your systems use. In other words, you're likely to be pleasantly surprised if you base your backup time estimation on your nameplate ratings, but perhaps not too happy if you find out you bought a UPS one or two sizes larger than you really needed. For calculating actual backup time, a good rule of thumb is that if your actual load is 3/4 of the UPS capacity, you usually can double your backup time, and if it is 1/2 loaded, you can usually triple your backup time. You are welcome to call for a recommendation for your application.

These outdoor UPS come with wide temperature batteries, and are engineered for extreme/severe weather conditions, typically -20° to +60°C (-4° to +140°F). Even lower temperatures -40° to +60°C (-40° to +140°F) can be accommodated with an optional battery heater. For high availability power for extreme mission-critical applications, redundant uninterruptible power systems, and/or motor-generators or dc-ac inverters are possible by adding an automatic transfer switch (ATS). Similar to the RAID concept of redundant arrays of inexpensive hard drives, ATS enables redundant arrays of inexpensive UPS.

Please note: UPS providing power sources for an ATS unit must provide a pure sine wave, even on battery backup, otherwise the ATS will not recognize it as a power source. Of the units below, all Outdoor-XUPs Series units have pure sine wave outputs, even on battery backup.

Typical outdoor uninterruptible power systems applications are:


Outdoor XUPs Series with automatic voltage regulation

Outdoor XUPs  ~ The Outdoor XUPs Series is a UPs system in an outdoor rated enclosure with wide temperature batteries and built-in automatic voltage regulation to handle brownouts and overvoltages within a wide voltage input window, without having to exercise the batteries, thus lengthening battery life. This is a heavy duty uninterruptible power system with a pure sine wave output. It has communications capability, a comprehensive array of status LED's and is relatively light weight.

As these systems are all build to order, please consider if you will need optional battery heaters for arctic or mountain top conditions, and how you will be mounting them, i.e. pole-mount, wall-mount or pad-mount. For OEMs, if your applications utilize very small components and if certain circumstances exist which would preclude you from using your own exterior cabinet, please look at if the units need to be built with enough room to enable your equipment to be housed inside, typically in the upper quadrant of the enclosure. And please call if you need the UPS to be built on a plate for use inside your OEM product. 

Typical Outdoor-XUPs configurations include, but are not limited to the following
(1st picture shows optional heavy-duty pole mounting brackets on one model):

Picture of Outdoor XUPs Series of wide temperature UPS with automatic voltage regulation.OutdoorXUPs-600A/B ~ 115 vac, 600 VA, 420 watts
OutdoorXUPs-1000A/B ~ 115 vac, 1 kVA, 700 watts
OutdoorXUPs-600A/BHV ~ 230 vac, 600 VA, 420 watts
OutdoorXUPs-1000A/BHV ~ 230 vac, 1 kVA, 700 watts

These wide temperature range UPS come in an outdoor rated NEMA 3R wall mountable enclosure, with dimensions of 24" high x 24" wide x 12" deep. Units are wall mountable (or pole or pad mountable with option heavy-duty mounting kits) and come with heavy-duty surge protection and a wide input voltage window.

Battery backup times vary per model from 40 minutes to 1.3 hours fully loaded, and more than double that when half loaded. These systems are ideal for perimeter surveillance systems, security gate control systems, LED traffic light/roadway display systems and industrial remote terminal units (RTUs).

Image of model Outdoor-UPs-8062/8061, 24V dc output UPS, with wide temperature batteries and heavy-duty surge protection in an outdoor NEMA 3R enclosure, wallmountable, polemountable or padmountable with optional mounting kits. 115V/115 vac, 120V/120 vac input, 24V dc/24 vdc output, 60 Hz.OutdoorXUPs-1500A/B ~ 115 vac, 1.5 kVA, 1050 watts
OutdoorXUPs-2200A/B ~ 115 vac, 2.2 kVA, 1540 watts
OutdoorXUPs-1500A/BHV ~ 230 vac, 1.5 kVA, 1050 watts
OutdoorXUPs-2200A/BHV ~ 230 vac, 2.2 kVA, 1540 watts
OutdoorXUPs-3000A/BHV ~ 230 vac, 3 kVA, 2100 watts

These larger size UPS come in an outdoor rated NEMA 3R wall mountable enclosure, with dimensions of 24" high x 24" wide x 16" deep or 30" high x 24" wide x 16" deep. Units are wall mountable (or pole or pad mountable with option heavy-duty mounting kits, though given their heavy weights, pad-mounting is the preferred method), and come with heavy-duty surge protection and a wide input voltage window.

Battery backup times vary per model from 45 minutes to 1.5 hours fully loaded, and more than double that when half loaded. These systems are ideal for perimeter surveillance systems, security gate control systems, LED traffic light/roadway display systems and industrial remote terminal units (RTUs).

Image of Outdoor-XUPs-600A-Mini outdoor UPS in a compact closure with wide temperature batteriesOutdoorXUPs-600A-Mini ~ 115 vac, 600 VA, 480 watts

These compact size systems come in an outdoor rated NEMA 3R wall mountable enclosure with dimensions of 20.5" high x 16.5" wide x 9.5" deep. Units are wall mountable through its standard bolt holes, or pole mountable with optional pole mounting kit, and all come with heavy-duty surge protection and a wide input voltage window.

Battery backup time is 0.6 hours fully loaded, and more than double that when half loaded. These systems are ideal for protection of WiMax/GSM/CDMA/satellite base stations, perimeter surveillance systems (CCTV), wireless communications and industrial remote terminal units (RTUs).

OutdoorXUPs-1200B-0780 ~ 115 vac, 1.5 kVA, 1050 wattsImage of Outdoor-XUPs-1200B, outdoor UPS with wide temperature batteries and long runtime

This larger size wide temperature UPS come in an outdoor rated NEMA 3R wall mountable enclosure, with dimensions of approximately 24" high x 24" wide x 16" deep. Units are wall mountable (or pole or pad mountable with option heavy-duty mounting kits, though given their heavy weights, pad-mounting is the preferred method), and come with heavy-duty surge protection and a wide input voltage window.

Battery backup times vary per model from 2.1 hours to 4.5 hours fully loaded, and more than double that when half loaded. These systems are ideal for perimeter surveillance systems, security gate control systems, LED traffic light/roadway display systems and industrial remote terminal units (RTUs).

Outdoor UPs: 115 vac input, with 24 vac output (please call).
Outdoor UPs: 230 vac input, with 24 vac output (please call).

Please call if your application requires other sizes or longer backup times.


Outdoor UPs Series

Image of OutdoorUPs-550 with wide temperature batteries, NEMA 3R/IP44 enclosure, and heavy-duty surge protectionOutdoor UPs  ~ these single conversion design outdoor UPS with communications capability have a backup time of 1.2 hours at 360 watts. These UPS systems have heavy-duty surge protection and filtering, under-voltage protection, and wide temperature batteries.

These units come in a NEMA 3R wall mountable enclosure, with dimensions of 16" high x 16" wide x 10" deep. Units are pole or pad mountable with optional heavy-duty mounting kits. These have a modified square wave output when on battery, suitable for most electronics, and thus are less expensive than the above pure sine wave XUPs units. As such, if you are interested in this particular model, even though almost all modern electronics will work with this, please confirm that your systems are modified square wave input compatible (most all modern switch-mode power supplies feeding modern PCs, etc. are). Note: these units are not automatic transfer switch (ATS) compatible. If redundant UPS are needed, please use the above Outdoor-XUPs Series units which are pure sine wave output even on battery.

Standard OutdoorUPs configurations include, but are not limited to:

OutdoorUPs-550 ~ 120 vac, 500 VA, 360 watts

Other sizes and backup times are available for OEM applications. Please call to discuss your system requirements.


UPS automatic shutdown software

Instructions for configuring Windows XP Professional for automatic shutdown with TSi UPS.

Please note:
Most recently introduced computer operating systems, even such as Windows XP Professional, have automatic shutdown elements incorporated, and may eliminate the need for a separate shutdown package. Please consult your operating system manual.  

UPS shutdown instructions ~ in Adobe PDF format.


Outdoor UPS features table

Features Outdoor UPS Series
  XUPs UPs
Wide voltage input window    
Automatic voltage regulation    
Extra battery cabinet ready    
Pure sine wave output    
Modified square wave output    
Heavy duty filtering and surge protection    
NEMA 3R/IP44 rated outdoor enclosure    
Communications capability    
Overcurrent protection - circuit breaker    

TSi Power also manufactures custom/bespoke outdoor uninterruptible power systems. Please call for more information.

Back to top                                       Back to Products overview page

Logo for OutdoorXUPs Series of wide temperature voltage regulated outdoor UPS.Logo for OutdoorUPS Series of outdoor wide temperature UPS.


En español    
 